Indian Journal of Science and Technology
DOI: 10.17485/ijst/2018/v11i23/125643
Year: 2018, Volume: 11, Issue: 23, Pages: 1-8
Original Article
Mary Christeena Thomas1*, Manohar 2 and G. Sundari3
1Embedded System, Sathyabama University, Jeppiaar Nagar, Rajiv Gandhi Road, Chennai – 600119, Tamil Nadu, India
2 Instrumentation-II, Ennore Thermal Power Station, Kathivakkam High Road, Girija Nagar, Ennore, Chennai – 600057, Tamil Nadu, India
3Department of Electronics and Communication Engineering, Jeppiaar Nagar, Rajiv Gandhi Road, Chennai – 600119, Tamil Nadu, India
*Author for correspondence
Mary Christeena Thomas,
Embedded System, Sathyabama University, Jeppiaar Nagar, Rajiv Gandhi Road, Chennai – 600119, Tamil Nadu, India
In Thermal power plant, Automatic Generation Control (AGC)is a system for adjusting the output power of multiple generators at different power plants, in response to load changes. Since a power grid requires load generation and closely balancing load moment by moment, frequent adjustments to the output of generators are mandatory. The balance can be predicted by measuring the system frequency; if it is rises, more power is being generated than used, which causes all the machines in the system to rise and accelerate. If the frequency of the system is decreasing, more supply of load is on the system than the instantaneous generation can provide, which causes all generators to slow down Load following power plants run during the day hours and early evening. They either shut down or greatly minimize the output during the night and early morning, when the demand for electricity is the lowest. The exact hours of operation depend on various factors. One of the most necessary factors for a particular plant is how efficiently it can convert fuel into electricity. The most efficient plants, which are almost invariably the less cost to run per kilowatt-hour produced, are brought online first. As demand increases, the next most efficient plants are brought on line and so on. The status of the electrical power grid in that particular region, especially how much is the capacity of base load generation. It has, and the variation in demand is also very crucial. An additional factor for operational variability is that excess demand does not deviate just between night and day. There are also significant variations in the time of year and day of the week. A region that has large variations in demand will require a huge load following or peaking power plant capacity because base load power plants can only cover the capacity equal to that needed during times of lowest demand.
Keywords: Blocking Control, Fuzzy Logic and Steam Governor, Smart Controller