• P-ISSN 0974-6846 E-ISSN 0974-5645

Indian Journal of Science and Technology

Article

Indian Journal of Science and Technology

Year: 2016, Volume: 9, Issue: 17, Pages: 1-5

Original Article

An Efficient Identification of Dynamic Faults using CAN and ARM7 in a Wind Turbine

Abstract

Background/objectives: This paper main focus on the monitoring and identifying the faults in the wind turbines. Methods and Analysis: In this paper we declare the system with ARM and CAN message protocol for monitoring and to diagnose the problems in the wind turbine. ARM core1 runs with CAN and LPC2148 works as a wind turbine unit to which sensors are connected and ARM core2 works as a monitoring section and also this system consists of a GSM modem which works as an intimate to the owner with an SMS to alert from dangerous situations and in necessary situations. Findings: Turbines working was changes under different climate conditions so using different sensors dynamic faults are outlined in turbine. Application/Improvement: wind turbines are extremely works in harsh environments so there is a need of observation by implementing this technique faults are outlined in future we can use many sensors.

Keywords: ARM7, CAN, GSM, RPM, Wind Turbine 