Indian Journal of Science and Technology
DOI: 10.17485/ijst/2011/v4i7.16
Year: 2011, Volume: 4, Issue: 7, Pages: 747-749
Original Article
Mukesh K. Lalji1 , R.M. Sarviya2 and J.L. Bhagoria2*
1Department of Technical Education and Skill Development, M.P. Govt. S.V. Polytechnic College, Shyamla Hills, Bhopal-462002 (M.P.);
2Department of Mechanical Engineering, MANIT Bhopal-462007 (M.P.), India
[email protected]
An experimental investigation has been done on a low porosity packed bed solar air heater. Investigation covers a wide range of geometrical parameters of wire screen matrices, i.e. wire diameter 0.48 mm, pitch 2.3 mm and number of layers from 3-6 and low range of porosity from 0.9614-0.9807 and packing Reynolds number range from 1064-2405. It is seen that heat transfer coefficient and friction factor are strong functions of geometrical parameters of the porous packed bed. A decrease in porosity increases the volumetric heat transfer coefficient.
Keywords: Solar air heater, heat transfer, wire screen matrices