Indian Journal of Science and Technology
DOI: 10.17485/ijst/2016/v9i26/97262
Year: 2016, Volume: 9, Issue: 26, Pages: 1-6
Original Article
Tabib Yousefi1*, Abdolreza Tavakoli2 , Farzad Arasteh3 and Abdollah Aghazadeh3
1 Technical and Vocational University, [email protected]
2 Department of Electrical Engineering, [email protected]
3 Electronic Branch, [email protected]
[email protected]
*Author for correspondence
Tabib Yousef
Technical and Vocational University,
Email: [email protected]
Background/Objectives: In this paper, tracking the Maximum Power Point for the Doubly Fed Induction Generators in the Wind Farm through a boost converter is analyzed. Methods/Statistical Analysis: Achieving maximum power at wind farm and subsequently improving power quality disturbances in power systems is very important. Methods used to track the maximum power point are: 1-TSR control 2-P&O control 3-ORB control This paper, presents a combination of P&O and ORB control method to extract maximum power at Doubly Fed Induction Generators (DFIG). Findings: In this method, there is no need to anemometer and the recent information of wind speed. In addition, the little Fluctuations near the maximum power point, is an improved factor in this technique. Simulation results using Matlab software, proves the truth of this claim.
Keywords: Boost Converter, Doubly Fed Induction Generators, Track Maximum Power Point, Wind Farm
Subscribe now for latest articles and news.