Indian Journal of Science and Technology
DOI: 10.17485/ijst/2017/v10i7/111452
Year: 2017, Volume: 10, Issue: 7, Pages: 1-5
Original Article
Joanne Zi En Soh* and Eko Supriyanto
Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, Johor Bahru, Johor – 81300, Malaysia; [email protected], [email protected]
*Author for the correspondence:
Joanne Zi En Soh
Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, Johor Bahru, Johor – 81300, Malaysia;
E-mail: [email protected]
Background/Objectives: Due to the low Reynolds number (Re) in microfluidic domain, the predominant laminar flow might inhibit effective mixing in micro-Coiled Flow Inverter (mCFI). Fluid dynamics within the mCFI was simulated with Computational Fluid Dynamics (CFD) software to investigate the mixing profile. Methods/Statistical Analysis: Fluid flow was simulated with the software FLUENT with Species Transport (ST) setting, to replicate the mixing of two water bodies. Geometry of the mCFI was designed with a tubing diameter of 0.5 mm and curvature ratio of λ = 10. Fluid flow rate was adjusted to attain 25≤ Re≤ 250. Findings: A mixing time of 0.59s was achieved with Re=250. However complete mixing was still achievable even in Re=25 albeit with a longer mixing time. Application/Improvements: Flow inversion is improved the mixing condition in micro-structured tubing, in enhancement of the diffusive mixing in microfluidics.
Keywords: Flow Inversion and Computational Fluid Dynamics (CFD), Micro-Coiled Flow Inverter (mCFIi), Reynolds Number