Indian Journal of Science and Technology
DOI: 10.17485/ijst/2016/v9i2/86350
Year: 2016, Volume: 9, Issue: 2, Pages: 1-8
Original Article
G. Jenitha* , V. Gokul Nath and N. Ganesh Kumar
Department of Civil Engineering, Vel Tech High Tech Dr. Rangarajan Dr. Sakunthala Engineering College, Chennai - 600062, Tamil Nadu, India; [email protected], [email protected], [email protected]
*Author For Correspondence
G. Jenitha
Department of Civil Engineering, Vel Tech High Tech Dr. Rangarajan Dr. Sakunthala Engineering College, Chennai - 600062, Tamil Nadu, India; [email protected]
Objective: This project deals with the experimental investigation of the two cold formed C beams, two cold-formed builtup C beams and one hot-rolled I beam. Methods/Statistical Analysis: An experimental setup is placed the specimens on the loading frame for static loading and cyclic loading for the C beams and I beam section. The load is applied axially along the centroid of the beam and it is distributed into two points loading by distributor. Findings: Determined the load and deflection behavior, stiffness, energy absorption and ductility with the number of cycles evaluated for cold-formed C beam and hot-rolled I beam. Applications: The load carrying capacity increases for the built-up member when compared to the ordinary member. Cold-formed beams are preferred to hot-rolled beams when thermal insulation, light weight nature, easy moulding and economy is considered.
Keywords: Built-Up, C Beams, Cyclic Loading and One Hot-Rolled I Beam