Evaluation and validation of the machine performance check application for TrueBeam 2.5 Linac

Received Date:08 April 2020, Accepted Date:24 April 2020, Published Date:28 May 2020

Abstract

Aim: To evaluate the Machine Performance Check (MPC) 1.1 application for TrueBeam 2.5 and to establish MPC application as a comprehensive daily QA tool after verification. Methodology: An automated daily Quality check application MPC using IsoCal Phantom provided by Varian Medical System (VMS) to perform the essential tests such as beam consistency that is dosimetric performance and mechanical check were performed on TrueBeam. The data was collected over a period of four months (84 days). MPC acquired data consists of a series of generation of images using MV and kV at various gantry, collimator, and couch positions. The collected data is analyzed for daily reproducibility as well as comparison with ion chamber measurements. Findings: The results showed that the reproducibility of MPC was less than the tolerance values for the respective mechanical parameters. The MPC measured isocenter with mean value of 0.35 mm is within tolerance. The Beam Consistency showed that over a period of four months, the mean value of output measurement of 6 MV photon beam as measured by the MPC and Farmer Type Chamber FC65-G differ by less than 1%. It is evident that the MPC proved to be fast and easy to use QA tool for daily checking of machine performance. But it is evident from present study that, inter comparison with a Farmer Type chamber is needed, if the MPC has to replace the other QA tools.

Keywords: MPC, QA, Linear Accelerator, EPID AS1000

References

  1. Klein EE, Hanley J, Bayouth J, Yin FF, Simon W, Dresser S, et al. Task Group 142 report: Quality assurance of medical accelerators) Medical Physics. 2009;36:4197–4212. doi: 10.1118/1.3190392
  2. Miften M, Olch A, Mihailidis D, Moran J, Pawlicki T, Molineu A, et al. Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218. Medical Physics. 2018;45(4):e53–e83. doi: 10.1002/mp.12810
  3. Dogan N. Tools for IMRT QA. Department of Radiation Oncology Virginia Commonwealth University, Medical College Of Virginia Hospitals, Richmond, VA, USA. 2005.
  4. Gao S, Du W, Balter P, Munro P, Jeung A. Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on-board imager and electronic portal imaging device imaging systems. Journal of Applied Clinical Medical Physics. 2014;15(3):164–181. doi: 10.1120/jacmp.v15i3.4688
  5. Clivio A, Vanetti E, Rose S, Nicolini G, Belosi MF, Cozzi L, et al. Evaluation of the Machine Performance Check application for TrueBeam Linac. Radiation Oncology. 2015;10(1):1–11. doi: 10.1186/s13014-015-0381-0
  6. Bhatt CP, Singh S, Chufal K, Semwal M. A preliminary investigation on long-term consistency of MPC as a quick daily QA application. International Journal of Cancer Therapy and Oncology. 2017;5(1). doi: 10.14319/ijcto.51.17
  7. Li Y, Netherton T, Nitsch PL, Gao S, Klopp AH, Balter PA, et al. Independent validation of machine performance check for the Halcyon and TrueBeam linacs for daily quality assurance. Journal of Applied Clinical Medical Physics. 2018;19(5):375–382. doi: 10.1002/acm2.12391
  8. Barnes MP, Pomare D, Menk FW, Moraro B, Greer PB. Evaluation of the truebeam machine performance check (MPC): OBI X-ray tube alignment procedure. Journal of Applied Clinical Medical Physics. 2018. doi: 10.1002/acm2.12445
  9. Armoogum K, Cornish G. EP-1749: Longterm stability of the Varian Truebeam Machine Performance Check (MPC) Radiotherapy and Oncology. 2018;127(18):S937–S938. doi: 10.1016/s0167-8140(18)32058-9

Copyright

© 2020 Nigam, Kumar, Singh, Silambarasan, Navitha. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Published By Indian Society for Education and Environment (iSee)

DON'T MISS OUT!

Subscribe now for latest articles and news.