Indian Journal of Science and Technology
DOI: 10.17485/ijst/2015/v8i33/81001
Year: 2015, Volume: 8, Issue: 33, Pages: 1-6
Original Article
S. S. Mirafzal1*, M. Khaleghi2 , M. Rahgoshay1 and M. Hashemi-Tilehnoee3
1 Department of Nuclear Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran; [email protected]
2 Department of Mechanical Engineering, Sirjan University of Technology, Kerman, Iran
3 Young Researchers and Elite Club, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, Iran;
The present work aims at verifying a sub-channel analysis program based on a drift-flux model by applying it to traditional VVER-1000 hot fuel assembly in steady-state and operational transients. Liquid enthalpy, mass velocity and liquid temperature calculated then compared with the final safety analysis report data. According to the results the code outputs are in good agreement with experimental data.
Keywords: Drift-Flux Model, Hot Fuel Assembly, Sub-Channel Analysis, VVER-1000