Indian Journal of Science and Technology
DOI: 10.17485/ijst/2015/v8i36/87643
Year: 2015, Volume: 8, Issue: 36, Pages: 1-5
Original Article
B. Srimanickam1*, M. M. Vijayalakshmi2 and E. Natarajan1
1 Institute for Energy Studies, Anna University, Chennai - 600 025, Tamil Nadu, India; [email protected], [email protected]
2 Department of Civil Engg, Sathyabama University, Chennai - 600 119, Tamil Nadu, India; [email protected]
This research study presents the thermal analysis of photovoltaic thermal hybrid system with cooling channel with V-baffles. Solar intensity, ambient temperature, inlet and outlet air channel temperature, glazing temperature, tedlar temperature, velocity of air inside the duct and mass flow rate of air are measured and used to calculate the thermal performance of photovoltaic thermal hybrid system. The maximum thermal, equivalent thermal and overall thermal efficiency of the PVT system with cooling channel with V-baffles are found to be 18.9%, 36.5% and 48.8% respectively. The present experimental performances is found to be in reasonable agreement with the earlier published results.
Keywords: Photovoltaic Thermal Hybrid System, Thermal Performance, V-Baffles